1-Roof garden,
2-Roof flowerpot
3-Greening wall
4-Raiwater catch basin
5-Automatic discharging device
6-Automatic Filter device
7- Sewerage discharging basin
8-Recovery basin
9-PP infiltration tank10-Geo membrance
11-Silty Sandy Clay
12-Back-purge system
13-Recovery system
14-Irrigation system
15-Infltration collect
16-Sewerage discharging system
17-Equipment foundation
18-Total dshargsig quantiy moitoring.

Looking for a smarter way to manage stormwater runoff on your project? The YS-Tank System provides the most efficient and versatile method of underground stormwater storage available today. It's an ideal way to convert stormwater ponds to useable space, and YS-Tank is a more efficient, space saving alternative for underground stormwater detention, infiltration, and recycling systems.
YS-Tank is a modular system and can be assembled to a variety of heights . This rigid system can be placed be-neath a variety of surfaces including: Parking Lots, Streets and Access Roads, Driveways, Landscaping, Athletic Fields/Playgrounds, Swales and Channels.
YS-Tank can be used for a variety of applications including: Retention and Infiltration, Detention, Recycling or Harvesting, Pond Retrofits, DryWells, and Bioretention.

High Capacity
95% void internal area
Strength
Easily supports traffic loading from parking lotsand roads
Backfill with sand - no stone required
Design & Construction Versatility
Combine modules into any shape to efficientlyuse space
Increased Infiltration and Exfiltration
Outer shell is 90% open
Increases groundwater recharge, reducing post-construction discharge
volumes
Easy to Transport
Can be supplied unassembled for reduceddelivery costs
Lightweight and Quick to Install
Installed by hand; no cranes required
Reduces site access delays
Recycled Content
Manufactured with recycled polypropylene

ItemNo:YS-6845
Size:680x410x450mm
Material:Recycle material
Compression Strength:25-35Tons/m2
Tanks:Per unit square meter include 3-7 pcs
Void Ratio:95%
9 small pics: one pallet in 20GP | 9 small pics: One 20GP | 9 small pics:one pallet in 40HQ | 9 small pics:One 40HQ |
967 pics | 9670 pics | 1102 pics | 24244 pics |
4 big pics + 1 samall pic:one pallet in 20GP | 4 big pics+ 1 samall pic:One20GP | 4 big pics+ 1 samall pic:one pallet in 40HQ | 4 big pics+ 1 samall pic:One 40HQ |
537 pics | 5370 pics | 612 pics | 13475 pics |






Installing the Maintenance System
To install the PCV Pipe, remove the center small plate and cut the top large plate between the remalning interior small plates. Before inserting the port into the Tank, install an anti-scour plate in the bottom of the Tank to prevent disturbance of the base materials.
Maintenance ports should be capped at the surface.In landscaped areas, this may be accomplished with a simple pipe cap or plasticvalve box. In paved areas, metal Tidsare moreappropriate.
Maintenance Intervals
Maintenance Schedules for the YS Tank System are a function of the contributing area and the type of pre-treatment specified. A standard maintenanceschedule may include quarterly inspections through the first year of use, with yearly inspections thereafter.Flushing should be performed if sediment should the lesser of 6" or 15% of the system height.